Features:
Operation voltage range from 2.4V to 26V with reverse voltage protection。
Operating temperature range from -25℃ to 80℃。
ON (Low) with magnetic South Pole and OFF (High) without magnetic field or with magnetic North Pole。
Built in a temperature compensated voltage regulator, a differential amplifier, a hysteresis controller and an open-collector output driver capable of sinking up to 20mA current load
Benefits:
High switching speed up to 10kHz。
Unaffected by harsh environments。
Long life;Up to 20 billion operations。
Customer selection of cable length and connector type。
Applications:
Position、Limit and Angle sensing。
RPM、Speed and Flow measurement。
Electrical Characteristics:
( T=+25℃, Vcc=2.4V to 26V )
| Characteristic |
Symbol |
Test Condition |
Min |
Typ |
Max |
Unit |
| Supply Voltage |
Vcc |
─ |
2.4 |
─ |
26 |
V |
| Output Saturation Voltage |
Vout (sat) |
Vcc=12V, Ic=10mA, B>Bop |
─ |
0.2 |
0.6 |
V |
| Output Leakage Current |
Leakage |
Vcc=12V, B<Bop |
─ |
<0.1 |
10 |
uA |
| Supply Current |
Supply |
Vcc=12V, Output Open |
─ |
2.0 |
5 |
mA |
| Output Rise Time |
Tr |
Vcc=12V, RL=2KΩ, CL=20pf |
─ |
1.0 |
10 |
μs |
| Output Falling Time |
Tf |
Vcc=12V, RL=2KΩ, CL=20pf |
─ |
0.3 |
1.5 |
μs |
Magnetic Characteristics:
| Characteristic |
Symbol |
Min |
Typ |
Max |
Unit |
| Operating Point |
Bop |
─ |
─ |
+80 |
Gauss |
| Release Point |
Brp |
+10 |
─ |
─ |
Gauss |
| Hysteresis Window |
Bhys |
─ |
10 |
30 |
Gauss |
| Dimensions Unit:mm |
 |
| Block Diagrams |
 |